Internal extension H1 prevents burner start
Breakdown: the boiler is stopped
On a Vitodens 200-W B2HB, 222-F B2TB or B2SB, or 222-W B2LB, the internal extension H1, an optional module in the control to which an external safety valve can be connected, or a device connected to it, stops the burner from starting: the burner stays blocked while the cause is there, without locking out. On a Vitodens 100-W B1HF, code 73 reports an internal communication fault: the burner locks out and the boiler only starts again after a reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Code 73 on a Vitodens 200-W B2HB, 222-F B2TB or B2SB, or 222-W B2LB: the burner is not locked out, do not reset the boiler.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show 73?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 73
The meaning depends on the boiler: find yours below.
The feedback signal input of the internal extension H1 prevents the burner from starting
The feedback message input of the internal extension H1 prevents the burner from starting
Internal communication fault
What our technician checks
- The connection and operation of the internal extension H1 and of the devices connected to it
- Plug 53/96: voltage interruption
- The unlocking, then the HBMU central electronic module if the fault persists (Vitodens 100-W B1HF)