Viessmann Fault code Viessmann
59

Hot water outlet sensor circuit broken

Blocking: it retries by itself

The outlet temperature sensor, which measures the hot water where it leaves the boiler, gives no reading any more: its circuit is broken; on a Vitotronic 300 KW3, 59 refers to the second sensor of the hot water cylinder, and on a Vitodens 100-W B1HF to a voltage that is too low on the boiler's central electronics module. On the other Vitodens, the boiler no longer makes hot water until the sensor is repaired; the Vitotronic 300 KW3 keeps controlling the hot water on one cylinder sensor; on the B1HF the burner and the pump stop, with no heating and no hot water as long as the voltage stays too low.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show 59?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 59

The meaning depends on the boiler: find yours below.

59

Open circuit of the outlet temperature sensor

Blocking: it retries by itself Vitodens 100-W B1HA, Vitodens 100-W B1HC, Vitodens 100-W WB1A, Vitodens 100-W WB1B, Vitodens 100-W WB1C, Vitodens 200 WB2A, Vitodens 200-W B2HA, Vitodens 200-W B2HB, Vitodens 200-W WB2B, Vitodens 200-W WB2C, Vitodens 222-F B2TA, Vitodens 222-F B2TB, Vitodens 222-F FS2A, Vitodens 222-F FS2B, Vitodens 222-W B2LA, Vitodens 222-W B2LB, Vitodens 222-W WS2A, Vitodens 222-W WS2B
59

Undervoltage of the HBMU central electronics module

Blocking: it retries by itself Vitodens 100-W B1HF
59

Open circuit DHW sensor 2

Blocking: it retries by itself Vitotronic 300 KW3

What our technician checks

  • The hot water outlet temperature sensor
  • The sensor's resistance, compared with the curve; to replace it, cold water shut off and the hot water side drained
  • Vitotronic 300 KW3: cylinder hot water sensor 2
  • Vitodens 100-W B1HF: the mains voltage; if it is correct and the fault comes back, the fan unit replaced

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.