Circuit 2 mixing valve kit wrongly set
Breakdown: the boiler is stopped
On a Vitodens 200-W B2HB, 222-F B2TB, 222-W B2LB, 300-W B3HB or B3HA, the mixing valve extension kit of heating circuit 2 is wrongly set and that valve closes; with a Vitotronic 300 KW3 control, the return sensor of that circuit is open circuit and the control carries on without the return temperature. On a Vitodens 100-W B1HF, code 49 reports an open-circuit flue gas temperature sensor: the burner locks out and the boiler only starts again after a reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Code 49 on a Vitodens 200-W B2HB, 222-F B2TB, 222-W B2LB, 300-W B3HB or B3HA, or with a Vitotronic 300 KW3 control: the burner is not locked out, do not reset the boiler.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show 49?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 49
The meaning depends on the boiler: find yours below.
Assignment of the mixing valve motor drive of heating circuit 2 set incorrectly
Coding of the mixing valve actuator for heating circuit 2 incorrectly set
Open circuit of the flue gas temperature sensor
Open circuit return sensor heating circuit M2
What our technician checks
- The rotary switch S1 of the mixing valve extension kit, which assigns the valve to heating circuit 2
- The coding of the mixing valve extension kit (Vitodens 300-W B3HA)
- The flue gas temperature sensor, then the unlocking (Vitodens 100-W B1HF)
- The return sensor of heating circuit M2 (Vitotronic 300 KW3)