Viessmann Fault code Viessmann
49

Circuit 2 mixing valve kit wrongly set

Breakdown: the boiler is stopped

On a Vitodens 200-W B2HB, 222-F B2TB, 222-W B2LB, 300-W B3HB or B3HA, the mixing valve extension kit of heating circuit 2 is wrongly set and that valve closes; with a Vitotronic 300 KW3 control, the return sensor of that circuit is open circuit and the control carries on without the return temperature. On a Vitodens 100-W B1HF, code 49 reports an open-circuit flue gas temperature sensor: the burner locks out and the boiler only starts again after a reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Code 49 on a Vitodens 200-W B2HB, 222-F B2TB, 222-W B2LB, 300-W B3HB or B3HA, or with a Vitotronic 300 KW3 control: the burner is not locked out, do not reset the boiler.
  3. Reset the boiler once only.
  4. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show 49?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 49

The meaning depends on the boiler: find yours below.

49

Assignment of the mixing valve motor drive of heating circuit 2 set incorrectly

Blocking: it retries by itself Vitodens 200-W B2HB, Vitodens 222-F B2TB, Vitodens 222-W B2LB, Vitodens 300-W B3HB
49

Coding of the mixing valve actuator for heating circuit 2 incorrectly set

Blocking: it retries by itself Vitodens 300-W B3HA
49

Open circuit of the flue gas temperature sensor

Breakdown: the boiler is stopped Vitodens 100-W B1HF
49

Open circuit return sensor heating circuit M2

Blocking: it retries by itself Vitotronic 300 KW3

What our technician checks

  • The rotary switch S1 of the mixing valve extension kit, which assigns the valve to heating circuit 2
  • The coding of the mixing valve extension kit (Vitodens 300-W B3HA)
  • The flue gas temperature sensor, then the unlocking (Vitodens 100-W B1HF)
  • The return sensor of heating circuit M2 (Vitotronic 300 KW3)

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.