Solar sensor or return sensor fault
Blocking: it retries by itself
On a Vitodens 200-W B2HB, 222-F B2TB or B2SB, 222-W B2LB or 300-W B3HB connected to solar collectors, a sensor on the hot water cylinder or the collectors reads outside its normal range; on a Vitotronic 200 KW2 or 300 KW3 control (floor-standing boilers), the return temperature sensor is short-circuited. The boiler keeps running (the Vitotronic regulates without taking the return temperature into account): it is a warning, for our technician to check.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show 21?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.