External flow temperature sensor faulty
Breakdown: the boiler is stopped
The external flow temperature sensor on the system's low loss header is faulty (break or short circuit); on the Cerapur ZWB-3, CerapurComfort ZWBR-3 and CerapurSmart this code also comes from a sensor that was unplugged and connected elsewhere after it had been detected. On a Cerapur ZWB-4 (D5 330, D5 331) it is a blocking fault: the boiler starts again by itself once the sensor works again; on the other models it stops and only starts again after a reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Codes D5 330 or D5 331 on a Cerapur ZWB-4: the boiler restarts by itself once the fault has cleared, do not reset it.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show d5?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code d5
The small number shown beside the code tells which.
External temperature limiter faulty. (low loss header) / The sensor of…
External flow temperature sensor faulty (low loss header)
External flow temperature sensor faulty (low loss header)
The boilers that show this code
What our technician checks
- The external temperature sensor and its cable (break, short circuit), replaced if needed
- Only one external flow sensor connected, the second one removed if there are two
- Resetting the Heatronic (function 8.E) and IPM 1 or IPM 2 to base settings, then the automatic system configuration with the thermostat