Junkers Fault code Junkers
EA

No flame detected

Breakdown: the boiler is stopped

The boiler does not detect a flame at its burner (no ionisation): the gas is not coming through, or the ignition, an electrode or the flue is at fault; on a Cerapur ZWB-4, EA 261 rather points to a timing fault of the control unit. It is a fault: the boiler stops and only starts again after a reset; on a Cerapur ZWB-4 (EA 227, EA 229) it first makes new ignition attempts by itself and only locks out after the fourth.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Check that the boiler's gas tap is open.
  3. Code EA 229 on a Cerapur ZWB-4: the boiler restarts by itself once the fault has cleared, do not reset it.
  4. Reset the boiler once only.
  5. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show EA?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code EA

The small number shown beside the code tells which.

EA

Flame not detected (no ionisation)

Breakdown: the boiler is stopped Cerapur, Cerapur ZWB-3, Cerapur ZWBR-3, CerapurSmart, Cerasmart, Eurostar ZWE-4, ZWC-3
EA
227

Flame is not detected

Breakdown: the boiler is stopped Cerapur ZWB-4
EA
229

No ionisation signal during burner operation

Blocking: it retries by itself Cerapur ZWB-4
EA
261

Timing fault 1st safety time

Breakdown: the boiler is stopped Cerapur ZWB-4

The boilers that show this code

What our technician checks

  • The gas tap and the gas supply pressure
  • The mains connection, the earthing and the coding plug
  • The ignition and ionisation electrodes and their cables, replaced if needed
  • The flue and the combustion air supply
  • The burner's gas/air ratio (CO2)
  • The condensate trap, the fan membrane and the heat exchanger, cleaned
  • The gas valve and, on natural gas, the external gas flow monitor (Cerapur ZWB-4), replaced if needed
  • For EA 261: the connectors and wiring to the control unit, then the control unit itself

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.