A temperature limiter has tripped
Breakdown: the boiler is stopped
A temperature limiter of the boiler has tripped: the one on the flow or on the heat exchanger, which protects the boiler from water that is too hot, or, on the Cerapur ZWB-3, CerapurComfort, CerapurSmart and Cerapur ZWB-4, the flue gas one; water pressure, air in the system and the circulating pump are the first things checked. It is a fault: the boiler stops and only starts again after a reset; on a Cerapur ZWB-4 (E9 224) it first waits for the fault to clear and only locks out if it lasts.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check the water pressure on the gauge, with the boiler cold: at least 1 bar. Too low? Top up as your installer showed you.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show E9?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E9
The small number shown beside the code tells which.
The temperature limiter in the flow or the flue gas temperature limiter…
The temperature limiter in the flow has tripped
The heat cell temperature limiter or the flue gas temperature limiter…
The boilers that show this code
What our technician checks
- The flow, heat exchanger and flue gas temperature limiters and their cables (break, short circuit), replaced if needed
- The heating system's operating pressure
- Bleeding the air from the boiler (service function 2.2C on a Cerapur ZWB-4)
- The circulating pump: operation, cable and power setting, replaced if needed
- The fuse on the circuit board
- The heat exchanger on the water side and, on a Cerapur ZWB-4, its displacement bodies