Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Junkers Fault code Junkers
C6

Fan or flue extraction fault

Breakdown: the boiler is stopped

The boiler finds that its fan is not turning, or not at the right speed (too fast for C6 215, too slow for C6 216 on a Cerapur ZWB-4); on a CeraclassExcellence ZWC-3 or a Eurostar ZWE-4, C6 means the flue pressure switch does not close. It is a fault: the boiler stops and only starts again after a reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show C6?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code C6

The small number shown beside the code tells which.

C6

The fan is not running

Breakdown: the boiler is stopped Cerapur ZWB-3, Cerapur ZWBR-3, CerapurSmart
C6

The pressure switch does not close

Breakdown: the boiler is stopped ZWC-3
C6

Pressure switch does not close

Breakdown: the boiler is stopped Eurostar ZWE-4
C6
215

Fan too fast

Breakdown: the boiler is stopped Cerapur ZWB-4
C6
216

Fan too slow

Breakdown: the boiler is stopped Cerapur ZWB-4

The boilers that show this code

What our technician checks

  • The fan, its cable and plug, replaced if needed
  • The fan, for dirt or a blockage (Cerapur ZWB-4)
  • The flue system, cleaned or repaired if needed
  • The pressure switch (CeraclassExcellence ZWC-3, Eurostar ZWE-4)

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.