Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Junkers Fault code Junkers
F0

Internal boiler fault

Breakdown: the boiler is stopped

The boiler's electronic control reports an internal fault, linked to a connection, an ignition lead, the circuit board or the gas/air setting; on a Cerapur ZWB-4 the number next to it gives the cause, for example F0 238 for the gas valve or its cable and F0 356 for an interrupted mains voltage. It is a fault: the boiler stops and only starts again after a reset; only F0 356 clears by itself once the power is back.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Code F0 356 on a Cerapur ZWB-4: the boiler restarts by itself once the fault has cleared, do not reset it.
  3. Reset the boiler once only.
  4. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show F0?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F0

The small number shown beside the code tells which.

F0

Internal error

Breakdown: the boiler is stopped Cerapur, Cerapur ZWB-3, Cerapur ZWBR-3, CerapurSmart, Cerasmart, ZWC-3
F0
238

Gas valve connecting cable, gas valve or control unit faulty

Breakdown: the boiler is stopped Cerapur ZWB-4
F0
239

Internal fault

Breakdown: the boiler is stopped Cerapur ZWB-4
F0
259

Internal fault

Breakdown: the boiler is stopped Cerapur ZWB-4
F0
280

Timing fault for the restart attempt

Breakdown: the boiler is stopped Cerapur ZWB-4
F0
290

Internal fault

Blocking: it retries by itself Cerapur ZWB-4
F0
356

Mains voltage interrupted

Blocking: it retries by itself Cerapur ZWB-4

The boilers that show this code

What our technician checks

  • The electrical plugs and connectors, the wiring and the ignition leads
  • The burner's gas/air ratio (CO2)
  • The bus module and how it is fitted (Cerasmart, older Cerapur)
  • For F0 238: the gas valve wiring and the gas valve, replaced if needed
  • For F0 239 and F0 259: the coding plug, replaced
  • For F0 356: the mains voltage
  • The circuit board or the control unit, replaced if needed

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.