Combustion control fault
Breakdown: the boiler is stopped
The boiler can no longer control its combustion: on the 2015 Thema Condens and IsoTwin Condens the stated cause is a corroded ignition electrode; on the CS/1 models the emergency mode has also failed and the cause may lie in the flue, the condensate, the gas or the electronics. This is a fault: the boiler stops and our technician has to find the cause before putting it back into service.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.57?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.57
The meaning depends on the boiler: find yours below.
Combustion control has failed and emergency mode has failed
Measurement fault
The boilers that show this code
What our technician checks
- The ignition electrode (corrosion)
- The whole flue gas path
- The condensate drain
- The dynamic gas pressure and the gas valve offset setting
- The fan: speed deviation read in D.033 and D.034
- The wiring harness and the circuit board