Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Bulex Fault code Bulex
F.57

Combustion control fault

Breakdown: the boiler is stopped

The boiler can no longer control its combustion: on the 2015 Thema Condens and IsoTwin Condens the stated cause is a corroded ignition electrode; on the CS/1 models the emergency mode has also failed and the cause may lie in the flue, the condensate, the gas or the electronics. This is a fault: the boiler stops and our technician has to find the cause before putting it back into service.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F.57?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.57

The meaning depends on the boiler: find yours below.

F.057

Combustion control has failed and emergency mode has failed

Breakdown: the boiler is stopped Isotwin Condens CS/1, Thema Condens CS/1
F.57

Measurement fault

Breakdown: the boiler is stopped Isotwin Condens, Thema Condens

The boilers that show this code

What our technician checks

  • The ignition electrode (corrosion)
  • The whole flue gas path
  • The condensate drain
  • The dynamic gas pressure and the gas valve offset setting
  • The fan: speed deviation read in D.033 and D.034
  • The wiring harness and the circuit board

Related codes