Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Bulex Fault code Bulex
F.42

Coding resistor fault

Breakdown: the boiler is stopped

The boiler does not recognise the coding resistor that tells it its output or gas type: short circuit, break in the resistor or in the heat exchanger harness. It is a fault: the boiler no longer knows how to run and waits for a technician.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F.42?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.42

The meaning depends on the boiler: find yours below.

F.042

The coding resistor (inside the wiring harness) or the resistor of the…

Breakdown: the boiler is stopped Isotwin Condens CS/1, Thema Condens CS/1
F.42

Coding resistor fault

Breakdown: the boiler is stopped Isotwin Condens, Thema Condens, ThemaClassic C30, Thematek C 18/24-LC/1

The boilers that show this code

What our technician checks

  • The connector, earth, cable and coding resistor
  • CS/1: the harness to the heat exchanger
  • ThemaClassic C30, ThemaTek: the gas group resistor
  • ThemaClassic C30, ThemaTek: the output coding resistor

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.