Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Bulex Fault code Bulex
F26

Gas valve fault or temperature difference

Breakdown: the boiler is stopped

On the dotted Thema Condens and IsoTwin Condens, the Thema Condens F and IsoTwin Condens F, the ThemaClassic C30 and the ThemaTek (F.26, F26), the gas valve does not respond: motor or modulation coil disconnected, broken or faulty. On the older ThermoMaster F, ThermoMaster HR TOP, Thema Condens F 24/30 and Isotwin (F26 without a dot), the maximum flow-return temperature difference has been reached, because the water circulates poorly; in both cases a technician is needed.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F26?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F26

The meaning depends on the boiler: find yours below.

F.26

Fuel valve fault, out of order

Breakdown: the boiler is stopped Isotwin Condens, Thema Condens
F.26

Break in the modulation coil (gas pressure regulator)

Breakdown: the boiler is stopped ThemaClassic C30, Thematek C 18/24-LC/1
F26

Gas valve motor fault

Breakdown: the boiler is stopped Isotwin Condens F, Thema Condens F
F26

Maximum temperature difference reached between heating flow and return

Breakdown: the boiler is stopped Isotwin, Thema Condens F 24/30, Thermomaster F
F26

Excessive temperature difference between flow temperature and return temperature

Breakdown: the boiler is stopped Thermomaster HR TOP

The boilers that show this code

What our technician checks

  • Dotted-code boilers: the gas valve stepper motor (connector, cable, coils, voltage)
  • ThemaClassic C30, ThemaTek: the harness and the modulation coil connections
  • The gas valve, then the circuit board, replaced if needed
  • Thema Condens F, IsoTwin Condens F: the condensate pump (option)
  • Older boilers: the flow and return sensor connections
  • Older boilers: the pump speed and circulation

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.