Hot water sensor or air supply fault
Breakdown: the boiler is stopped
On the dotted Thema Condens and IsoTwin Condens (F.02, F.002) and on the IsoTwin Condens F (F02), the boiler no longer receives the signal from its hot water sensor. On the older ThermoMaster F, Thema Condens F 24/30, Isotwin, ThermoMaster HR TOP and Isotwin/Isomax (F2 without a dot), it is a flue or air supply fault: the safety device stops the boiler; on an Isotwin or Isomax of type C (connected to a chimney), it restarts by itself after 15 minutes.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Smell of flue gas in the house? Open doors and windows wide, switch the boiler off and call us.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show F2?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F2
The meaning depends on the boiler: find yours below.
The hot water connection temperature sensor signal has been interrupted
Domestic hot water outlet sensor open circuit
Fault in the temperature sensor for domestic hot water circuit control
Air extraction or air intake fault
Extraction fault
Air extraction or intake fault
Air flow safety device on F models / Flue spillage safety device on C models
The boilers that show this code
What our technician checks
- Dotted-code boilers: the hot water sensor's connector and cable
- Dotted-code boilers: the hot water sensor, replaced if needed
- Dotted-code boilers: the wiring harness and, with a stratified cylinder, its connections
- Older boilers: the air supply and the flue
- Older boilers: the pressure switch and the fan, and their connections
- Older boilers: the room's high and low vents
- ThermoMaster HR TOP: the external supply safety device and its wiring