Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Bulex Fault code Bulex
F2

Hot water sensor or air supply fault

Breakdown: the boiler is stopped

On the dotted Thema Condens and IsoTwin Condens (F.02, F.002) and on the IsoTwin Condens F (F02), the boiler no longer receives the signal from its hot water sensor. On the older ThermoMaster F, Thema Condens F 24/30, Isotwin, ThermoMaster HR TOP and Isotwin/Isomax (F2 without a dot), it is a flue or air supply fault: the safety device stops the boiler; on an Isotwin or Isomax of type C (connected to a chimney), it restarts by itself after 15 minutes.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Smell of flue gas in the house? Open doors and windows wide, switch the boiler off and call us.
  3. Reset the boiler once only.
  4. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show F2?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F2

The meaning depends on the boiler: find yours below.

F.002

The hot water connection temperature sensor signal has been interrupted

Breakdown: the boiler is stopped Isotwin Condens CS/1, Thema Condens CS/1
F.02

Domestic hot water outlet sensor open circuit

Breakdown: the boiler is stopped Isotwin Condens, Thema Condens
F02

Fault in the temperature sensor for domestic hot water circuit control

Breakdown: the boiler is stopped Isotwin Condens F
F2

Air extraction or air intake fault

Breakdown: the boiler is stopped Thema Condens F 24/30, Thermomaster F
F2

Extraction fault

Breakdown: the boiler is stopped Thermomaster HR TOP
F2

Air extraction or intake fault

Breakdown: the boiler is stopped Isotwin
F2

Air flow safety device on F models / Flue spillage safety device on C models

Breakdown: the boiler is stopped Isotwin-Isomax

The boilers that show this code

What our technician checks

  • Dotted-code boilers: the hot water sensor's connector and cable
  • Dotted-code boilers: the hot water sensor, replaced if needed
  • Dotted-code boilers: the wiring harness and, with a stratified cylinder, its connections
  • Older boilers: the air supply and the flue
  • Older boilers: the pressure switch and the fan, and their connections
  • Older boilers: the room's high and low vents
  • ThermoMaster HR TOP: the external supply safety device and its wiring

Related codes