Hot water sensor short or communication fault
Breakdown: the boiler is stopped
On the dotted Bulex boilers (Thema Condens, IsoTwin Condens, ThemaClassic C30: F.12, F.012) and on the IsoTwin Condens F (F12), the hot water sensor is short-circuited. On the older ThermoMaster F, ThermoMaster HR TOP, Thema Condens F 24/30 and Isotwin (F12 without a dot), it is a communication fault: link with the room thermostat, the control interface or the eBUS line; in both cases a technician is needed.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F12?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F12
The meaning depends on the boiler: find yours below.
The hot water connection temperature sensor is short-circuited
Domestic hot water outlet sensor short circuit
Domestic hot water temperature sensor short circuit
Fault in the temperature sensor for domestic hot water circuit control
Communication error
No signal on the user interface
EBUS voltage fault
The boilers that show this code
What our technician checks
- Dotted-code boilers: the hot water sensor, replaced if needed
- Dotted-code boilers: the sensor cable and the wiring harness
- With a stratified cylinder: connector, harness, sensor and circuit board
- Thema Condens F 24/30, Isotwin: the load on the eBUS line
- ThermoMaster HR TOP: the wiring, the interface and parameter 23
- ThermoMaster F: the link with the room thermostat, then a restart