Bulex Fault code Bulex
F12

Hot water sensor short or communication fault

Breakdown: the boiler is stopped

On the dotted Bulex boilers (Thema Condens, IsoTwin Condens, ThemaClassic C30: F.12, F.012) and on the IsoTwin Condens F (F12), the hot water sensor is short-circuited. On the older ThermoMaster F, ThermoMaster HR TOP, Thema Condens F 24/30 and Isotwin (F12 without a dot), it is a communication fault: link with the room thermostat, the control interface or the eBUS line; in both cases a technician is needed.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F12?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F12

The meaning depends on the boiler: find yours below.

F.012

The hot water connection temperature sensor is short-circuited

Breakdown: the boiler is stopped Isotwin Condens CS/1, Thema Condens CS/1
F.12

Domestic hot water outlet sensor short circuit

Breakdown: the boiler is stopped Isotwin Condens, Thema Condens
F.12

Domestic hot water temperature sensor short circuit

Breakdown: the boiler is stopped ThemaClassic C30
F12

Fault in the temperature sensor for domestic hot water circuit control

Breakdown: the boiler is stopped Isotwin Condens F
F12

Communication error

Breakdown: the boiler is stopped Thermomaster F
F12

No signal on the user interface

Breakdown: the boiler is stopped Thermomaster HR TOP
F12

EBUS voltage fault

Breakdown: the boiler is stopped Isotwin, Thema Condens F 24/30

The boilers that show this code

What our technician checks

  • Dotted-code boilers: the hot water sensor, replaced if needed
  • Dotted-code boilers: the sensor cable and the wiring harness
  • With a stratified cylinder: connector, harness, sensor and circuit board
  • Thema Condens F 24/30, Isotwin: the load on the eBUS line
  • ThermoMaster HR TOP: the wiring, the interface and parameter 23
  • ThermoMaster F: the link with the room thermostat, then a restart

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.