Abnormal water temperature, boiler locked out
Breakdown: the boiler is stopped
On boilers with the MCBA controller (Prestige MkII, Prestige 50, 75 and 120, HeatMaster TC before 2015, HeatMaster 71, 101 and 201), E83 means the water in the second heating circuit is too hot (NTC6 sensor, optional), pointing to the three-way valve or its motor; on boilers with the ACVMax or ACVMax Touch controller (Prestige from 2014, HeatMaster TC from 2015, HeatMaster Evo, WaterMaster), it means the difference between the water leaving the boiler (flow) and the water coming back (return) is too large, pointing to the water circulation or the pump. In both cases the boiler locks out and only starts again after a reset.
What you can do
- Write down the code shown and the boiler model, without opening the appliance.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show E83?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E83
The meaning depends on the boiler: find yours below.
NTC6 sensor temperature too high
Delta T protection lockout
What our technician checks
- The three-way valve and its motor (MCBA)
- The water circulation in the system (ACVMax, ACVMax Touch)
- The pump: seized or clogged, freed or replaced if needed (ACVMax, ACVMax Touch)