ACV Fault code ACV
E03

Overheating or gas valve fault

Breakdown: the boiler is stopped

On a Prestige MkIII or a HeatMaster 25 C with the ESYS controller, and on a recent Prestige or HeatMaster with the ACVMax screen (Evo included), E03 means overheating: the boiler water has gone above 105 °C (ACVMax) or 110 °C (ESYS), or the limit thermostat has opened (ESYS); on a Prestige MkII or a HeatMaster TC from before 2015 (MCBA controller), it means a fault of the gas valve or of its drive (TRIAC). In every case the boiler locks out for safety and only starts again after a reset.

What you can do

  1. Write down the code shown and the boiler model, without opening the appliance.
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show E03?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code E03

The meaning depends on the boiler: find yours below.

E03

Gas valve or TRIAC error

Breakdown: the boiler is stopped MCBA
E03

Maximum thermostat input open / T1 or T2 > 110°C

Breakdown: the boiler is stopped ESYS
E03

Excessive temperature

Breakdown: the boiler is stopped ACVMax, ACVMax Touch

What our technician checks

  • The gas valve and its rectifier, replaced if needed (MCBA)
  • The limit thermostat (ESYS)
  • The NTC sensor wiring, replaced if needed (ESYS)
  • Water flow through the boiler and the pipes (radiator valves)
  • The pump and its electrical connection (ACVMax)

Related codes