Overheating or gas valve fault
Breakdown: the boiler is stopped
On a Prestige MkIII or a HeatMaster 25 C with the ESYS controller, and on a recent Prestige or HeatMaster with the ACVMax screen (Evo included), E03 means overheating: the boiler water has gone above 105 °C (ACVMax) or 110 °C (ESYS), or the limit thermostat has opened (ESYS); on a Prestige MkII or a HeatMaster TC from before 2015 (MCBA controller), it means a fault of the gas valve or of its drive (TRIAC). In every case the boiler locks out for safety and only starts again after a reset.
What you can do
- Write down the code shown and the boiler model, without opening the appliance.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show E03?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E03
The meaning depends on the boiler: find yours below.
Gas valve or TRIAC error
Maximum thermostat input open / T1 or T2 > 110°C
Excessive temperature
What our technician checks
- The gas valve and its rectifier, replaced if needed (MCBA)
- The limit thermostat (ESYS)
- The NTC sensor wiring, replaced if needed (ESYS)
- Water flow through the boiler and the pipes (radiator valves)
- The pump and its electrical connection (ACVMax)