ACV Fault code ACV
E25

Temperature rising too fast or internal error

Breakdown: the boiler is stopped

On a Prestige MkII or a HeatMaster TC from before 2015 (MCBA controller), E25 means that the flow temperature (T1) is rising too fast, which points to the pump or to air in the system; on a Prestige MkIII or a HeatMaster 25 C with the ESYS controller, and on a recent Prestige or HeatMaster with the ACVMax screen (Evo included), it means an internal error of the controller (CRC check). In every case the boiler locks out and only starts again after a reset.

What you can do

  1. Write down the code shown and the boiler model, without opening the appliance.
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show E25?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code E25

The meaning depends on the boiler: find yours below.

E25

T1 gradient too high

Breakdown: the boiler is stopped MCBA
E25

CRC error

Breakdown: the boiler is stopped ESYS
E25

Internal control error

Breakdown: the boiler is stopped ACVMax, ACVMax Touch

What our technician checks

  • Whether the pump is running (MCBA)
  • Bleeding the system, if the pump is in order (MCBA)
  • A reset of the system, otherwise the ESYS board, replaced if needed (ESYS)
  • Switching the boiler off and on (ACVMax)

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.