Too many resets or internal error
Breakdown: the boiler is stopped
On a recent Prestige or HeatMaster with the ACVMax screen (Evo included), E13 means that the maximum number of resets has been reached (5 per 15 minutes); on a Prestige MkIII or a HeatMaster 25 C with the ESYS controller, it means an error of the remote reset, and on a Prestige MkII or a HeatMaster TC from before 2015 (MCBA controller), an internal error of the controller. The boiler stays locked out: with the ACVMax screen, switching it off and on brings it back; with ESYS, a reset done on the boiler itself; with MCBA, a reset.
What you can do
- Write down the code shown and the boiler model, without opening the appliance.
- ACVMax screen: do not reset again; switch the boiler off with its on/off switch and back on, once only.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show E13?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E13
The meaning depends on the boiler: find yours below.
Internal error
Remote "RESET" error
Maximum number of resets reached
What our technician checks
- Switching the boiler off and on, then the ACVMax board, replaced if the fault persists (ACVMax)
- A local reset on the boiler, then the ESYS board, replaced if the fault persists (ESYS)
- The MCBA board, to be replaced or reprogrammed if the fault persists after two resets (MCBA)