ACV Fault code ACV
E07

Flue gas too hot or gas valve relay

Breakdown: the boiler is stopped

On a Prestige MkIII or a HeatMaster 25 C with the ESYS controller, and on a recent Prestige or HeatMaster with the ACVMax screen (Evo included), E07 means the flue gas is too hot; on a Prestige MkII or a HeatMaster TC from before 2015 (MCBA controller), it means a fault of the gas valve relay. With the ACVMax screen the boiler starts again by itself once the flue gas temperature is back to normal; with MCBA and ESYS it locks out and only starts again after a reset.

What you can do

  1. Write down the code shown and the boiler model, without opening the appliance.
  2. ACVMax screen: the boiler restarts by itself once the flue gas has cooled down, do not reset it.
  3. Do not reset the boiler: call us.

Does your boiler show E07?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code E07

The meaning depends on the boiler: find yours below.

E07

Gas valve relay error

Breakdown: the boiler is stopped MCBA
E07

Flue gas temperature too high (NTC5)

Breakdown: the boiler is stopped ESYS
E07

Excessive flue gas temp.

Blocking: it retries by itself ACVMax, ACVMax Touch

What our technician checks

  • The NTC5 flue gas sensor, its connection and wiring, replaced if needed (ESYS)
  • The heat exchanger, cleaned if needed (ACVMax)
  • The MCBA board, to be replaced or reprogrammed if the fault persists after two resets (MCBA)

Related codes