Ignition failure or false flame
Breakdown: the boiler is stopped
On a Prestige MkII or a HeatMaster TC from before 2015 (MCBA controller), E02 means an ignition failure: no flame after five start attempts; on a Prestige MkIII or a HeatMaster 25 C with the ESYS controller, and on a recent Prestige or HeatMaster with the ACVMax screen (Evo included), it means the opposite, a false flame, an abnormal flame signal, detected before ignition on ACVMax. In every case it is a safety fault: the boiler locks out and only starts again after a reset.
What you can do
- Write down the code shown and the boiler model, without opening the appliance.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show E02?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E02
The meaning depends on the boiler: find yours below.
No flame presence signal after five start attempts
Abnormal flame presence signal detected
False flame
What our technician checks
- The ignition cable (MCBA, ESYS)
- The electrode: position and cleanliness
- Gas reaching the burner (MCBA)
- The earth connections (ACVMax)
- The ESYS board, replaced if there is water damage (ESYS)