Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
ACV Fault code ACV
E05

Fan or flame detection fault

Breakdown: the boiler is stopped

On a Prestige MkIII or a HeatMaster 25 C with the ESYS controller, and on a recent Prestige or HeatMaster with the ACVMax screen (Evo included), E05 means a fan fault: its speed is wrong or the controller receives no signal from it; on a Prestige MkII or a HeatMaster TC from before 2015 (MCBA controller), it means that no flame is detected or that the power supply is of poor quality. In every case the boiler locks out and only starts again after a reset.

What you can do

  1. Write down the code shown and the boiler model, without opening the appliance.
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show E05?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code E05

The meaning depends on the boiler: find yours below.

E05

No flame detection or poor quality of the supply current

Breakdown: the boiler is stopped MCBA
E05

No tachometer signal from the fan

Breakdown: the boiler is stopped ESYS
E05

Fan speed

Breakdown: the boiler is stopped ACVMax, ACVMax Touch

What our technician checks

  • The fan, its wiring and its PWM connection (ESYS, ACVMax)
  • The fan, then the ESYS board, replaced if the fault persists after two resets (ESYS)
  • The electrode gap (MCBA)
  • The resistance (kΩ) of the electrode cable (MCBA)
  • The stability of the power supply (MCBA)

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.