Flame detection fault or air pressure switch
Breakdown: the boiler is stopped
On a Prestige MkIII or a HeatMaster 25 C with the ESYS controller, and on a recent Prestige or HeatMaster with the ACVMax screen (Evo included), E08 means a flame detection problem: no flame detected (ESYS) or the flame circuit test has failed (ACVMax); on a Prestige MkII or a HeatMaster TC from before 2015 (MCBA controller), it means that the air pressure switch has not closed. In every case the boiler locks out and only starts again after a reset.
What you can do
- Write down the code shown and the boiler model, without opening the appliance.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show E08?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E08
The meaning depends on the boiler: find yours below.
The air pressure switch has not closed
No flame detection
Flame circuit error
What our technician checks
- The electrode: gap and resistance, 1 kΩ (ESYS)
- The electrode, checked and cleaned with the boiler switched off (ACVMax)
- The ignition and earth cable connections (ACVMax)
- The air pressure switch (MCBA)