ACV Fault code ACV
E12

Limit thermostat open or internal error

Breakdown: the boiler is stopped

On a Prestige MkII or a HeatMaster TC from before 2015 (MCBA controller), E12 means that the limit thermostat input is open or that the controller's 24 V fuse is damaged; on a recent Prestige or HeatMaster with the ACVMax screen (Evo included), it means an internal error: the EEPROM memory is wrongly configured. In both cases the boiler locks out and only starts again after a reset.

What you can do

  1. Write down the code shown and the boiler model, without opening the appliance.
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show E12?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code E12

The meaning depends on the boiler: find yours below.

E12

Maximum thermostat input open or 24 V fuse damaged

Breakdown: the boiler is stopped MCBA
E12

Internal error

Breakdown: the boiler is stopped ACVMax, ACVMax Touch

What our technician checks

  • The limit thermostat (MCBA)
  • The 24 V fuse of the MCBA board (MCBA)
  • The 12-13 jumper or the connected external thermostat (MCBA)
  • Switching the boiler off and on, then the ACVMax board, replaced if the fault persists (ACVMax)

Related codes