Limit thermostat open or internal error
Breakdown: the boiler is stopped
On a Prestige MkII or a HeatMaster TC from before 2015 (MCBA controller), E12 means that the limit thermostat input is open or that the controller's 24 V fuse is damaged; on a recent Prestige or HeatMaster with the ACVMax screen (Evo included), it means an internal error: the EEPROM memory is wrongly configured. In both cases the boiler locks out and only starts again after a reset.
What you can do
- Write down the code shown and the boiler model, without opening the appliance.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show E12?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E12
The meaning depends on the boiler: find yours below.
Maximum thermostat input open or 24 V fuse damaged
Internal error
What our technician checks
- The limit thermostat (MCBA)
- The 24 V fuse of the MCBA board (MCBA)
- The 12-13 jumper or the connected external thermostat (MCBA)
- Switching the boiler off and on, then the ACVMax board, replaced if the fault persists (ACVMax)