ACV Fault code ACV
E37

Water pressure too low or sensor open

Breakdown: the boiler is stopped

On a recent Prestige or HeatMaster with the ACVMax screen (Evo included), E37 means that the water pressure of the system has dropped below 0.7 bar, and on a Prestige MkIII or a HeatMaster 25 C with the ESYS controller, a water pressure problem; on a Prestige MkII or a HeatMaster TC from before 2015 (MCBA controller), it means that the return sensor (NTC2) circuit is open. With the ACVMax screen the boiler starts again by itself once the pressure is restored; with ESYS and MCBA it locks out and only starts again after a reset.

What you can do

  1. Write down the code shown and the boiler model, without opening the appliance.
  2. Prestige MkIII or ACVMax screen: check the water pressure (gauge or screen), at least 1 bar with the boiler cold. Too low? Switch the boiler off and top up in small amounts, as your installer showed you.
  3. ACVMax screen: the boiler restarts by itself once the pressure is restored, do not reset it.
  4. Do you often have to top up? Call us.
  5. Reset the boiler once only.
  6. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show E37?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code E37

The meaning depends on the boiler: find yours below.

E37

NTC2 open

Breakdown: the boiler is stopped MCBA
E37

Water pressure

Breakdown: the boiler is stopped ESYS
E37

Low water level

Blocking: it retries by itself ACVMax, ACVMax Touch

What our technician checks

  • The water pressure of the system (ESYS, ACVMax)
  • The NTC2 return sensor, its connection and wiring (MCBA)
  • The NTC2 sensor, replaced if the fault persists (MCBA)

Related codes