Flame loss or return too hot
Breakdown: the boiler is stopped
On a recent Prestige or HeatMaster with the ACVMax screen (Evo included), E19 means a flame loss: the flame goes out after the boiler has started; on a Prestige MkII or a HeatMaster TC from before 2015 (MCBA controller), it means that the return temperature (T2) has gone above 110 °C. In both cases the boiler locks out and only starts again after a reset.
What you can do
- Write down the code shown and the boiler model, without opening the appliance.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show E19?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E19
The meaning depends on the boiler: find yours below.
T2 > 110°C
Flame failure
What our technician checks
- The flue ducts: no blockage (ACVMax)
- The combustion settings: CO2 at maximum and minimum output (ACVMax)
- The electrode rod: distance to the burner and cleanliness (ACVMax)
- The NTC sensor wiring, replaced if needed (MCBA)