Flow too hot or sensor failure
Breakdown: the boiler is stopped
On a Prestige MkII or a HeatMaster TC from before 2015 (MCBA controller), E18 means that the flow temperature (T1) has gone above 110 °C; on a recent Prestige or HeatMaster with the ACVMax screen (Evo included), it means a sensor failure: the value read by the flow or return sensor changes too fast. In both cases the boiler locks out and only starts again after a reset.
What you can do
- Write down the code shown and the boiler model, without opening the appliance.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show E18?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code E18
The meaning depends on the boiler: find yours below.
T1 > 110°C
Sensor failure
What our technician checks
- The NTC sensor wiring, replaced if needed (MCBA)
- The water flow through the boiler, if the NTC1 sensor is in order (MCBA)
- The flow and return sensors and their wiring (ACVMax)