Flame lost while running
Breakdown: the boiler is stopped
The burner lost its flame while it was lit, during its stabilisation phase or in full operation (Vitodens 200-W B2HB, 222-F B2TB and B2SB, 222-W B2LB). For safety the burner locks out: the boiler stops heating and only starts again after a reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check that the gas supply valve is open; if it is, ask your gas supplier (on propane: check the tank level).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show Fb?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code Fb
The meaning depends on the boiler: find yours below.
Loss of flame during the stabilisation or operating phase
Flame loss during the operating or stabilisation phase
What our technician checks
- The gas supply: gas pressure and gas flow monitor
- Flue gas recirculation in the flue and air intake ducts
- The ionisation electrode: distance to the burner gauze and fouling