Viessmann Fault code Viessmann
19

Configuration or wireless outdoor sensor fault

Blocking: it retries by itself

On a Vitodens 200-W B2HA, 222-F B2TA or B2SA, 222-W B2LA or 300-W (B3HA, B3HB), the controller no longer receives the wireless outdoor temperature sensor; on a Vitodens 200-W B2HB, 222-F B2TB or B2SB, 222-W B2LB and on a Vitotronic 200 KO1B control (floor-standing boilers), a controller setting is wrong (configuration fault). In both cases the boiler keeps running and regulates as if it were 0 °C outside: it is a warning, for our technician to put right.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show 19?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 19

The meaning depends on the boiler: find yours below.

19

Configuration fault

Blocking: it retries by itself Vitodens 200-W B2HB, Vitodens 222-F B2SB, Vitodens 222-F B2TB, Vitodens 222-W B2LB, Vitotronic 200 KO1B
19

Communication loss of the RF outside temperature sensor

Blocking: it retries by itself Vitodens 200-W B2HA, Vitodens 300-W B3HB
19

Communication fault with the radio outside temperature sensor

Blocking: it retries by itself Vitodens 222-F B2SA, Vitodens 222-F B2TA
19

Communication interruption of the RF outside temperature sensor

Blocking: it retries by itself Vitodens 222-W B2LA
19

Communication interruption of the radio outside temperature sensor

Blocking: it retries by itself Vitodens 300-W B3HA

What our technician checks

  • The radio link: outdoor sensor moved closer to the radio base or the boiler
  • The wireless outdoor sensor, unregistered and registered again, replaced if needed
  • Parameter 2A (wireless outdoor sensor) set to 0 (Vitodens 200-W B2HB, 222-F B2TB and B2SB, 222-W B2LB)
  • Coding 2E set to 0 in the General group (Vitotronic 200 KO1B)

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.