Solar collector sensor short circuit
Blocking: it retries by itself
On the Vitodens 200-W (B2HB, B2HA, WB2C, WB2B), 200 WB2A and 300-W (B3HB, B3HA) and the Vitotronic 100 KC2B and 200 KO1B controls, the solar collector temperature sensor has a short circuit: the boiler keeps heating, but on most of these models the hot water is no longer heated by the sun until our technician has checked the sensor. On a Vitodens 100-W B1HF, this number reports a communication fault with the ADIO electronics module, whose function switches to emergency mode, and our technician must check its connections.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show 92?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 92
The meaning depends on the boiler: find yours below.
Short circuit of the collector temperature sensor
Short circuit of the collector temperature sensor, connection on S1 on the Vitosolic
Short circuit of the collector temperature sensor, connection of the temperature sensor &…
Communication fault of the electronics module ADIO
Short circuit of the collector temperature sensor, connection of temperature sensor 6 to…
Short circuit of the collector temperature sensor, connection to S1 on the Vitosolic
What our technician checks
- The collector sensor (sensor 6) on the solar control module, or the sensor on terminal S1 of the Vitosolic solar controller
- The setting in the commissioning assistant, corrected if needed (Vitodens 100-W B1HF)
- The connections and cables of the ADIO electronics module (Vitodens 100-W B1HF)
- The PlusBus voltage, 24 to 28 V (Vitodens 100-W B1HF)
- The node number on rotary switch S1 (Vitodens 100-W B1HF)