Insufficient gas supply during calibration
Breakdown: the boiler is stopped
On the Vitodens 200-W B2HB, 222-F B2TB, 222-F B2SB and 222-W B2LB, the boiler did not get enough gas during its calibration. It is a fault: the boiler locks out its burner and only starts again after a reset, and our technician must check the gas pressure and supply.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check that the boiler's gas valve is open.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show 85?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 85
The meaning depends on the boiler: find yours below.
Insufficient gas supply during calibration
What our technician checks
- The static gas pressure and the supply pressure
- The sizing of the gas pipe and of the gas flow limiter
- The gas valve inlet and its strainer, fouled for example after the gas pipe was brazed