Flame signal present before ignition
Breakdown: the boiler is stopped
On the Vitodens 200-W B2HB, 222-F B2TB, 222-F B2SB and 222-W B2LB, the boiler already sees a flame signal when the burner starts, before it has lit anything. It is a fault: the boiler locks out its burner and only starts again after a reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show 83?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 83
The meaning depends on the boiler: find yours below.
Flame signal already present when the burner starts
What our technician checks
- Condensate build-up in the installation
- The ionisation and ignition electrodes: damage, short circuit to earth (contact with the insulating ring), removing the fan unit first, then the burner
- The connecting cables of the ionisation and ignition electrodes
- The control unit, replaced if the fault persists