Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Viessmann Fault code Viessmann
83

Flame signal present before ignition

Breakdown: the boiler is stopped

On the Vitodens 200-W B2HB, 222-F B2TB, 222-F B2SB and 222-W B2LB, the boiler already sees a flame signal when the burner starts, before it has lit anything. It is a fault: the boiler locks out its burner and only starts again after a reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show 83?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 83

The meaning depends on the boiler: find yours below.

83

Flame signal already present when the burner starts

Breakdown: the boiler is stopped Vitodens 200-W B2HB, Vitodens 222-F B2SB, Vitodens 222-F B2TB, Vitodens 222-W B2LB

What our technician checks

  • Condensate build-up in the installation
  • The ionisation and ignition electrodes: damage, short circuit to earth (contact with the insulating ring), removing the fan unit first, then the burner
  • The connecting cables of the ionisation and ignition electrodes
  • The control unit, replaced if the fault persists

Related codes