Viessmann Fault code Viessmann
80

Insufficient gas supply

Breakdown: the boiler is stopped

The boiler is not getting enough gas: gas pressure too low, or a gas line or gas flow monitor that is wrongly sized. The burner locks out and the boiler only starts again after a reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Check that the boiler's gas tap is open.
  3. Reset the boiler once only.
  4. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show 80?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 80

The meaning depends on the boiler: find yours below.

80

Insufficient gas supply

Breakdown: the boiler is stopped Vitodens 200-W B2HB, Vitodens 222-F B2SB, Vitodens 222-F B2TB, Vitodens 222-W B2LB

What our technician checks

  • The static gas pressure and the working gas pressure, measured
  • The sizing of the gas line and of the gas flow monitor
  • The house gas pressure regulator: a pressure that rises with the burner off shows it is leaking

Related codes