Insufficient gas supply
Breakdown: the boiler is stopped
The boiler is not getting enough gas: gas pressure too low, or a gas line or gas flow monitor that is wrongly sized. The burner locks out and the boiler only starts again after a reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check that the boiler's gas tap is open.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show 80?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 80
The meaning depends on the boiler: find yours below.
Insufficient gas supply
What our technician checks
- The static gas pressure and the working gas pressure, measured
- The sizing of the gas line and of the gas flow monitor
- The house gas pressure regulator: a pressure that rises with the burner off shows it is leaking