Flue gas limiter tripped or ventilation fault
Breakdown: the boiler is stopped
On a Vitodens 100-W B1HF the flue gas temperature limiter has tripped and cut the burner: the boiler locks out and only starts again after a reset, once the flue has cooled down. On a Vitodens 300-W B3HB connected to a ventilation unit, 63 means a fault in that ventilation unit, which has its own fault codes, and our technician needs to check it.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Vitodens 100-W B1HF: check the water pressure on the display; below 1.0 bar it is too low: top up only if your installer has shown you how, otherwise call us.
- Does the code stay on or come back? Do not take anything apart: call us.
- Do not reset the boiler: call us.
Does your boiler show 63?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 63
The meaning depends on the boiler: find yours below.
See "Ventilation system fault messages " page 117
The flue gas temperature limiter has tripped
What our technician checks
- Vitodens 100-W B1HF: the system fill level and the expansion vessel pre-charge pressure
- Vitodens 100-W B1HF: the water flow (circulation pump) and the 3-way diverter valve
- Vitodens 100-W B1HF: bleeding the air out of the system, then unlocking the appliance once the flue has cooled down
- Vitodens 300-W B3HB: the ventilation unit's fault code, shown with the « 63: ventilation » button, and the table of ventilation system fault codes