Safety limiter tripped or ventilation link disturbed
Breakdown: the boiler is stopped
On a Vitodens 100-W B1HF the safety temperature limiter has tripped and cut the burner: the boiler locks out and only starts again after a reset, and our technician looks for the cause (water level, expansion vessel, flow, 3-way valve, air in the system). On a Vitodens 300-W B3HB connected to a ventilation unit, 62 only means the communication between the ventilation unit and the control panel is disturbed: the ventilation unit keeps running with its last settings or in basic mode.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Vitodens 100-W B1HF: check the water pressure on the display; below 1.0 bar it is too low: top up only if your installer has shown you how, otherwise call us.
- Vitodens 100-W B1HF only: reset the boiler once only.
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show 62?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 62
The meaning depends on the boiler: find yours below.
Communication between the ventilation unit and the control unit is disrupted
The safety temperature limiter has tripped
What our technician checks
- Vitodens 100-W B1HF: the system fill level and the expansion vessel pre-charge pressure
- Vitodens 100-W B1HF: the water flow (circulation pump) and the 3-way diverter valve
- Vitodens 100-W B1HF: bleeding the air out of the system, then unlocking the appliance
- Vitodens 300-W B3HB: the ventilation unit and the Modbus cable to the LM1 ventilation control module
- Vitodens 300-W B3HB: the ventilation unit's controller board, replaced if needed
- Vitodens 300-W B3HB, if fault EF is shown: the device connected to the Modbus