Viessmann Fault code Viessmann
62

Safety limiter tripped or ventilation link disturbed

Breakdown: the boiler is stopped

On a Vitodens 100-W B1HF the safety temperature limiter has tripped and cut the burner: the boiler locks out and only starts again after a reset, and our technician looks for the cause (water level, expansion vessel, flow, 3-way valve, air in the system). On a Vitodens 300-W B3HB connected to a ventilation unit, 62 only means the communication between the ventilation unit and the control panel is disturbed: the ventilation unit keeps running with its last settings or in basic mode.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Vitodens 100-W B1HF: check the water pressure on the display; below 1.0 bar it is too low: top up only if your installer has shown you how, otherwise call us.
  3. Vitodens 100-W B1HF only: reset the boiler once only.
  4. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show 62?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 62

The meaning depends on the boiler: find yours below.

62

Communication between the ventilation unit and the control unit is disrupted

Blocking: it retries by itself Vitodens 300-W B3HB
62

The safety temperature limiter has tripped

Breakdown: the boiler is stopped Vitodens 100-W B1HF

What our technician checks

  • Vitodens 100-W B1HF: the system fill level and the expansion vessel pre-charge pressure
  • Vitodens 100-W B1HF: the water flow (circulation pump) and the 3-way diverter valve
  • Vitodens 100-W B1HF: bleeding the air out of the system, then unlocking the appliance
  • Vitodens 300-W B3HB: the ventilation unit and the Modbus cable to the LM1 ventilation control module
  • Vitodens 300-W B3HB: the ventilation unit's controller board, replaced if needed
  • Vitodens 300-W B3HB, if fault EF is shown: the device connected to the Modbus

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.