Flow sensor or buffer tank sensor broken
Blocking: it retries by itself
On a Vitodens 100-W B1HC, B1HA, WB1C or WB1B, 5A means the flow sensor or its cable is broken: the burner stays blocked until the sensor is repaired. On a floor-standing boiler with a Vitotronic 100 KC2B or 200 KO1B control, it means the buffer tank temperature sensor is broken: the buffer tank is no longer heated.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show 5A?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 5A
The meaning depends on the boiler: find yours below.
Open circuit of the flow rate sensor
Open circuit of the flow sensor
Open circuit of the buffer cylinder temperature sensor
What our technician checks
- The flow sensor's connections and cable, sensor replaced if needed (Vitodens 100-W)
- The buffer tank temperature sensor (Vitotronic 100 KC2B, 200 KO1B)
- Without a buffer tank sensor: coding 52:0 in the General group (Vitotronic 100 KC2B, 200 KO1B)