Viessmann Fault code Viessmann
5A

Flow sensor or buffer tank sensor broken

Blocking: it retries by itself

On a Vitodens 100-W B1HC, B1HA, WB1C or WB1B, 5A means the flow sensor or its cable is broken: the burner stays blocked until the sensor is repaired. On a floor-standing boiler with a Vitotronic 100 KC2B or 200 KO1B control, it means the buffer tank temperature sensor is broken: the buffer tank is no longer heated.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show 5A?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 5A

The meaning depends on the boiler: find yours below.

5A

Open circuit of the flow rate sensor

Blocking: it retries by itself Vitodens 100-W B1HC
5A

Open circuit of the flow sensor

Blocking: it retries by itself Vitodens 100-W B1HA, Vitodens 100-W WB1B, Vitodens 100-W WB1C
5A

Open circuit of the buffer cylinder temperature sensor

Blocking: it retries by itself Vitotronic 100 KC2B, Vitotronic 200 KO1B

What our technician checks

  • The flow sensor's connections and cable, sensor replaced if needed (Vitodens 100-W)
  • The buffer tank temperature sensor (Vitotronic 100 KC2B, 200 KO1B)
  • Without a buffer tank sensor: coding 52:0 in the General group (Vitotronic 100 KC2B, 200 KO1B)

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.