20-minute wait after flue gas escape
Blocking: it retries by itself
The atmoVIT, the atmoTEC and turboTEC VU/VUW /3 and the atmoTEC VUW 244/4-5 have detected flue gas escaping and block their burner for 20 minutes; on the atmoTEC VUW /5-5 the code reports too high a flue gas temperature, and on an ecoTEC plus or pro VC/VCW /3 a water pressure above 2.9 bar. It is a wait, not a locked fault: the boiler restarts by itself, but flue gas that keeps escaping must be checked without delay.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Smell flue gas in the room? Open doors and windows wide, switch the boiler off and call us.
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show S.52?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code S.52
The meaning depends on the boiler: find yours below.
Water pressure > 2.9 bar
The appliance is within the 20-minute waiting time of the lock-out function
The appliance is in a 20-minute pause due to the escape of
Excessive flue gas temperature
Product in a 20-minute waiting period due to escape of flue gases
The boilers that show this code
What our technician checks
- The flue: defect or blockage
- The chimney draught
- The combustion air supply to the room
- An extractor fan or cooker hood causing backdraught
- The flue gas temperature (atmoTEC VUW /5-5)
- The system water pressure (ecoTEC VC/VCW /3)