Vaillant Fault code Vaillant
S.52

20-minute wait after flue gas escape

Blocking: it retries by itself

The atmoVIT, the atmoTEC and turboTEC VU/VUW /3 and the atmoTEC VUW 244/4-5 have detected flue gas escaping and block their burner for 20 minutes; on the atmoTEC VUW /5-5 the code reports too high a flue gas temperature, and on an ecoTEC plus or pro VC/VCW /3 a water pressure above 2.9 bar. It is a wait, not a locked fault: the boiler restarts by itself, but flue gas that keeps escaping must be checked without delay.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Smell flue gas in the room? Open doors and windows wide, switch the boiler off and call us.
  3. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show S.52?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code S.52

The meaning depends on the boiler: find yours below.

S.52

Water pressure > 2.9 bar

Blocking: it retries by itself VCW /3
S.52

The appliance is within the 20-minute waiting time of the lock-out function

Blocking: it retries by itself VK /1-5
S.52

The appliance is in a 20-minute pause due to the escape of

Blocking: it retries by itself VUW /3-5
S.52

Excessive flue gas temperature

Information: nothing to do VUW /5-5
S.52

Product in a 20-minute waiting period due to escape of flue gases

Blocking: it retries by itself VUW /4-5

The boilers that show this code

What our technician checks

  • The flue: defect or blockage
  • The chimney draught
  • The combustion air supply to the room
  • An extractor fan or cooker hood causing backdraught
  • The flue gas temperature (atmoTEC VUW /5-5)
  • The system water pressure (ecoTEC VC/VCW /3)