+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Vaillant Fault code Vaillant
F.13

Cylinder temperature sensor short circuit

Breakdown: the boiler is stopped

The hot water cylinder's temperature sensor (or the warm-start or preheating sensor on some combination boilers) is short-circuited: the boiler reads an impossible value, because of the sensor or a cable touching earth. It is a fault code: the boiler no longer works normally and needs a technician.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F.13?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.13

The meaning depends on the boiler: find yours below.

F.013

The storage temperature sensor is short-circuited.

Breakdown: the boiler is stopped VCW CS/1-5, VCW CS/1-7
F.13

Cylinder sensor short circuit

Breakdown: the boiler is stopped VC /8-5, VCW /3, VCW /5-7, VK /1-5, VKK /4, turboVIT combi
F.13

Storage temperature sensor short circuit

Breakdown: the boiler is stopped VCW /5-5
F.13

Short circuit at the cylinder temperature sensor

Breakdown: the boiler is stopped VC /4-5, VC 486/5-5, VUW /5-5
F.13

Hot start flow temperature sensor / cylinder sensor short circuit (NTC)

Breakdown: the boiler is stopped VUW /3-5
F.13

Short circuit on the storage temperature sensor/preheating temperature sensor

Breakdown: the boiler is stopped VUW /4-5
F.13

Storage sensor short circuit

Breakdown: the boiler is stopped VCC /4
F.13

Cylinder NTC short circuit (> 130 °C)

Breakdown: the boiler is stopped VSC /2

The boilers that show this code

What our technician checks

  • The cylinder sensor, replaced if needed
  • The connecting cable, replaced if needed
  • The wiring harness and the earth connection
  • The sensor connector and the circuit board
  • With a stratified cylinder: its connections to the circuit board

Related codes