Overheat safety device tripped
Breakdown: the boiler is stopped
The overheat safety device has cut the gas: the flow or return sensor measured too high a temperature (lack of water, air, pump), or a loose electrical contact tripped it. It is a safety shutdown: the boiler does not heat until the cause is found; on the atmoVIT and turboVIT, the limiter is unlocked by hand, on the appliance.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.20?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.20
The meaning depends on the boiler: find yours below.
The overheat cut-off (STB) has cut the gas valve control
The safety temperature limiter has tripped
Safety shutdown temp. limiter
Safety shutdown: temperature limiter
Safety shutdown: overheat cut-off
The temperature limiter has tripped Manual reset on the limiter!
Overheat cut-off signal
The boilers that show this code
What our technician checks
- The flow and return sensors: loose contact, thermal contact with the pipe
- The earth connection
- The ignition cable, connector and electrode (discharge to the casing)
- Filling, bleeding and tightness of the system
- The pump and the three-way valve
- The water pressure and flow sensors
- The wiring harness and its connectors