Ignition failure at start-up
Breakdown: the boiler is stopped
The boiler tried several times to light its burner without sensing a flame: for example a closed gas tap, too low a gas pressure, air in the gas pipe, or an ignition fault. It goes into fault mode and stops heating; a reset starts a new ignition attempt.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check that the boiler's gas tap is open.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show F.28?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.28
The meaning depends on the boiler: find yours below.
The flame signal was not detected during the ignition phase.
The appliance does not start: ignition attempts fail
Start fault Ignition unsuccessful
Start-up fault: ignition failure
Ignition failure
Fault at appliance start-up Ignition attempts remain unsuccessful at the
Start-up fault: ignition failed (5 times)
In the event of a fault during appliance start-up: ignition attempts failed
The boilers that show this code
What our technician checks
- The gas tap and the dynamic gas pressure
- The gas pressure switch, the meter and the thermal shut-off device
- The gas valve and its setting (offset, air-gas ratio, CO2)
- The ignition system: transformer, cable, electrode
- The ionisation electrode, its cable and plug
- The appliance earth
- The condensate drain and the flue
- The multi-pin connector, the harness and the circuit board