Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Vaillant Fault code Vaillant
F.28

Ignition failure at start-up

Breakdown: the boiler is stopped

The boiler tried several times to light its burner without sensing a flame: for example a closed gas tap, too low a gas pressure, air in the gas pipe, or an ignition fault. It goes into fault mode and stops heating; a reset starts a new ignition attempt.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Check that the boiler's gas tap is open.
  3. Reset the boiler once only.
  4. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show F.28?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.28

The meaning depends on the boiler: find yours below.

F.028

The flame signal was not detected during the ignition phase.

Breakdown: the boiler is stopped VCW CS/1-5, VCW CS/1-7
F.28

The appliance does not start: ignition attempts fail

Breakdown: the boiler is stopped VCW /3, VSC /2
F.28

Start fault Ignition unsuccessful

Breakdown: the boiler is stopped VC /8-5, VCW /5-3, VCW /5-5, VCW /5-7, VKK /4
F.28

Start-up fault: ignition failure

Breakdown: the boiler is stopped VC /4-5, VC 806/5-5, VCC /4, VUW /4-5, VUW /5-5
F.28

Ignition failure

Breakdown: the boiler is stopped VC 486/5-5
F.28

Fault at appliance start-up Ignition attempts remain unsuccessful at the

Breakdown: the boiler is stopped VK /1-5, turboVIT combi
F.28

Start-up fault: ignition failed (5 times)

Breakdown: the boiler is stopped VKK /5
F.28

In the event of a fault during appliance start-up: ignition attempts failed

Breakdown: the boiler is stopped VUW /3-5

The boilers that show this code

What our technician checks

  • The gas tap and the dynamic gas pressure
  • The gas pressure switch, the meter and the thermal shut-off device
  • The gas valve and its setting (offset, air-gas ratio, CO2)
  • The ignition system: transformer, cable, electrode
  • The ionisation electrode, its cable and plug
  • The appliance earth
  • The condensate drain and the flue
  • The multi-pin connector, the harness and the circuit board

Related codes