Flame detected with the burner off
Breakdown: the boiler is stopped
The boiler sees a flame signal while the burner is off and the gas valve closed: a leaking gas valve, moisture or a fault on the circuit board, or a fouled electrode. It is a safety shutdown: the boiler switches off and should only be put back into service after a check.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.27?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.27
The meaning depends on the boiler: find yours below.
A flame signal was detected while the burner is off.
Stray light
Safety shutdown Flame simulation
Safety shutdown: flame simulation
The ionisation signal indicates a flame despite the gas valve being closed
"Stray light"
Stray light signal, the ionisation signal indicates a flame despite the gas valve being off
Safety shutdown: incorrect flame detection
Stray light: ionisation signal reports flame despite gas valve closed
The boilers that show this code
What our technician checks
- The gas solenoid valve: tightness and operation
- The circuit board (moisture), replaced if needed
- The flame monitor
- The monitoring or ionisation electrode
- The gas pressure at the upper test point
- atmoTEC, turboTEC: fouling of the combustion chamber