Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Vaillant Fault code Vaillant
N.096

Gas valve at its upper control limit

Breakdown: the boiler is stopped

The motor that sets the gas valve opening has reached the end of its range, on the maximum side. The appliance switches to emergency mode, with reduced comfort, and the code does not clear by itself: our technician has to step in.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show N.096?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code N.096

The meaning depends on the boiler: find yours below.

N.096

The stepper motor of the gas valve has reached the maximum permissible number of steps.

Breakdown: the boiler is stopped VCW CS/1-5, VCW CS/1-7

What our technician checks

  • The gas supply pressure
  • The gas type and its setting (D.156 and D.157)
  • The gas valve offset setting (D.052)
  • The wiring harness and electrical connection of the gas valve
  • The circuit board, to be replaced if faulty
  • The air mass flow sensor, if fitted (air intake kit): fouling

Related codes