Hot water sensor disconnected
Breakdown: the boiler is stopped
The boiler no longer receives the signal from the sensor that measures the domestic hot water (hot water outlet, or stratified cylinder on some ecoTEC plus and ecoTEC exclusive; cylinder charging sensor on the ecoCOMPACT VSC): the sensor, its cable or a connector is at fault. It is a fault code: the boiler no longer works normally and needs a technician.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.02?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.02
The meaning depends on the boiler: find yours below.
The signal from the hot water connection temperature sensor has been interrupted.
Outlet sensor interruption
DHW outlet sensor interruption
DHW outlet sensor open circuit
DHW outlet temperature sensor interruption (NTC)
DHW outlet sensor interruption
Supply temperature NTC sensor interruption
The boilers that show this code
What our technician checks
- The wiring between the circuit board and the sensor, connectors included
- The hot water sensor, replaced if needed
- With a stratified cylinder: its connector, wiring and sensor
- The connection of the cylinder electronics