Hot water sensor short circuit
Breakdown: the boiler is stopped
The sensor that measures the domestic hot water (hot water outlet, or cylinder charging sensor on the ecoTEC plus VCW /5-5, the ecoTEC exclusive with actoSTOR and the ecoCOMPACT VSC) is short-circuited: the boiler reads an impossible value, because of the sensor or a cable touching earth. It is a fault code: the boiler no longer works normally and needs a technician.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.12?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.12
The meaning depends on the boiler: find yours below.
The hot water connection temperature sensor is short-circuited.
Outlet sensor short circuit
DHW outlet temperature sensor short circuit (NTC)
DHW outlet sensor short circuit
Cylinder charging NTC short circuit (> 130 °C)
The boilers that show this code
What our technician checks
- The hot water sensor, replaced if needed
- The wiring between the circuit board and the sensor, connectors included
- A short in the harness or against the casing
- With a stratified cylinder: connector, harness, sensor and circuit board