Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Vaillant Fault code Vaillant
F.01

Return temperature sensor disconnected

Breakdown: the boiler is stopped

The boiler no longer receives the signal from its return temperature sensor, which measures the water coming back from the heating: the sensor, its cable or a connector is at fault. It is a fault code: the boiler no longer works normally and needs a technician.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F.01?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.01

The meaning depends on the boiler: find yours below.

F.001

The signal from the return temperature sensor is interrupted.

Breakdown: the boiler is stopped VCW CS/1-5, VCW CS/1-7
F.01

Return temperature sensor interruption

Breakdown: the boiler is stopped VC 486/5-5, VC 806/5-5, VCC /4, VCW /5-3, VCW /5-5
F.01

Return sensor open circuit

Breakdown: the boiler is stopped VC /8-5, VCW /5-7
F.01

Open circuit in the return temperature sensor

Breakdown: the boiler is stopped VUW /5-5
F.1

Return temperature sensor interruption (NTC)

Breakdown: the boiler is stopped VCW /3, VUW /3-5
F.1

Open circuit in the return temperature sensor

Breakdown: the boiler is stopped VC /4-5
F.1

Return temperature sensor interruption

Breakdown: the boiler is stopped VUW /4-5
F.1

Heating return NTC interruption

Breakdown: the boiler is stopped VSC /2

The boilers that show this code

What our technician checks

  • The return temperature sensor's connector and cable
  • The return temperature sensor, replaced if needed
  • The multi-pin connector on the circuit board
  • The wiring harness, for a break
  • The circuit board

Related codes