Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Vaillant Fault code Vaillant
F.22

Not enough water in the boiler

Breakdown: the boiler is stopped

The boiler has no water or not enough: the heating system pressure is too low (below 0.5 bar on an ecoTEC plus), or the boiler no longer measures it correctly (pressure sensor, cable, pump). It is a safety shutdown: the boiler stops so as not to fire dry.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Check the water pressure on the display or the gauge. Too low? Top up with water, as your installer showed you.
  3. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F.22?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.22

The meaning depends on the boiler: find yours below.

F.022

There is no water, or not enough water, in the product, or the water pressure is too low.

Breakdown: the boiler is stopped VCW CS/1-5, VCW CS/1-7
F.22

dry firing

Breakdown: the boiler is stopped VCW /3, VSC /2
F.22

Safety shutdown lack of water

Breakdown: the boiler is stopped VC /8-5, VCW /5-3, VCW /5-5, VCW /5-7, VKK /4
F.22

Safety shutdown: lack of water

Breakdown: the boiler is stopped VC /4-5, VC 486/5-5, VC 806/5-5, VCC /4, VKK /5, VUW /4-5, VUW /5-5
F.22

Appliance operating without water

Breakdown: the boiler is stopped VUW /3-5

The boilers that show this code

What our technician checks

  • Filling the system and bleeding it
  • Leaks in the boiler and the system
  • The water pressure sensor, replaced if needed
  • The cable to the pump and to the pressure sensor
  • The heating pump
  • The wiring harness
  • The automatic filling loop and the internal expansion vessel

Related codes