Flow-return temperature difference too large
Breakdown: the boiler is stopped
The water leaving for the heating is much hotter than the water coming back: water circulates poorly in the boiler, for example a blocked or weak pump, air or lack of water, or flow and return sensors swapped. It is a safety shutdown: the boiler stops to protect itself.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check the water pressure on the display or the gauge. Too low? Top up with water, as your installer showed you.
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.23?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.23
The meaning depends on the boiler: find yours below.
The temperature difference between flow and return is too high.
Lack of water, temperature difference between flow and return sensors too large
Safety shutdown temp. difference too high
Safety shutdown: temperature difference too high
Lack of water, temperature difference between flow and return sensors too great
Lack of water (flow/return temperature difference too high)
The boilers that show this code
What our technician checks
- The pump: operation and output
- Bleeding the system and its water content
- The connection of the flow and return sensors (swapped)
- The flow and return sensors and their wiring
- The three-way valve and the internal expansion vessel
- The hydraulic block strainer and the water pressure sensor