Flame signal too weak
Breakdown: the boiler is stopped
The boiler does not get enough signal from its flame electrode to control its combustion (the drift test or adaptation failed): recirculating flue gas, blocked condensate drain, gas pressure or type, electrode, gas valve or burner. It is a fault: the boiler stops until a technician has been.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.044?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.044
The meaning depends on the boiler: find yours below.
The ionisation signal of the monitoring electrode is insufficient
Drift test fault
What our technician checks
- The flue and the air intake pipe
- The condensate drain, trap and pump included
- The dynamic gas pressure and the gas type
- The combustion chamber: electrodes, insulation, burner
- The ionisation electrode, replaced if needed
- The gas valve
- The wiring harness and the circuit board