Gas valve at its minimum limit
Breakdown: the boiler is stopped
The motor of the gas valve, which meters gas to the burner, has reached the lower limit of its adjustment, which points to a problem in the flue path, the condensate drain, the gas setting or a component. The boiler goes into fault mode and stops until the cause is fixed and it is reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.095?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.095
The meaning depends on the boiler: find yours below.
The stepper motor of the gas valve has reached the minimum permissible number of steps.
Gas valve min. limit fault
What our technician checks
- The whole flue gas path (recirculation, blockage)
- The condensate drain pipe
- The combustion chamber: electrodes, insulation, burner
- The condensate pump, if fitted
- The gas type and its setting
- The gas valve offset setting
- The gas valve, its connection and its wiring harness
- The control (ionisation) electrode and the circuit board, replaced if needed