Gas valve at its maximum limit

Breakdown: the boiler is stopped

The motor of the gas valve, which meters gas to the burner, has reached the upper limit of its adjustment, which points for example to a gas supply pressure that is too low, or to a problem with the gas setting or a component. The boiler goes into fault mode and stops until the cause is fixed and it is reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F.096?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.096

The meaning depends on the boiler: find yours below.

F.096

The stepper motor of the gas valve has reached the maximum permissible number of steps.

Breakdown: the boiler is stopped VCW CS/1-5, VCW CS/1-7
F.96

Gas valve max. limit fault Communication fault

Breakdown: the boiler is stopped VC /8-5

What our technician checks

  • The gas supply pressure at the boiler
  • The whole flue gas path
  • The gas type and its setting
  • The gas valve offset setting
  • The condensate drain pipe, the trap and the condensate pump
  • The gas valve, its connection and its wiring harness
  • The control (ionisation) electrode and the burner
  • The circuit board, replaced if needed