Gas valve at its maximum limit
Breakdown: the boiler is stopped
The motor of the gas valve, which meters gas to the burner, has reached the upper limit of its adjustment, which points for example to a gas supply pressure that is too low, or to a problem with the gas setting or a component. The boiler goes into fault mode and stops until the cause is fixed and it is reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.096?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.096
The meaning depends on the boiler: find yours below.
The stepper motor of the gas valve has reached the maximum permissible number of steps.
Gas valve max. limit fault Communication fault
What our technician checks
- The gas supply pressure at the boiler
- The whole flue gas path
- The gas type and its setting
- The gas valve offset setting
- The condensate drain pipe, the trap and the condensate pump
- The gas valve, its connection and its wiring harness
- The control (ionisation) electrode and the burner
- The circuit board, replaced if needed