Gas valve at its lower control limit

Blocking: it retries by itself

The motor that sets the gas valve opening has reached the end of its range, on the minimum side. The appliance switches to emergency mode, with reduced comfort, and the code clears by itself as soon as the cause is gone.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show L.095?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code L.095

The meaning depends on the boiler: find yours below.

L.095

The gas valve stepper motor has reached the minimum permissible number of steps

Blocking: it retries by itself VCW CS/1-5, VCW CS/1-7

What our technician checks

  • The whole flue gas path (recirculation, blockage)
  • The condensate drain pipe
  • The gas type and its setting (D.156 and D.157)
  • The gas valve offset setting (D.052)
  • The wiring harness and electrical connection of the gas valve
  • The control electrode, replaced if needed
  • The circuit board, to be replaced if faulty
  • The air mass flow sensor, if fitted (air intake kit): fouling